Indian J Sex Transm Dis Indian J Sex Transm Dis
Official Publication of the Indian Association for the Study of Sexually Transmitted Diseases
Indian J Sex Transm Dis
The Journal | Search | Ahead Of Print | Current Issue | Archives | Instructions | Subscribe | Login    Users online: 14   Home Email this page Print this page Bookmark this page Decrease font size Default font size Increase font size
 
ORIGINAL ARTICLE
Ahead of Print

Does performance and operational superiority of point-of-care test make it the investigation of choice in confirming syphilis?


1 Apex Regional STD Centre, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India
2 Department of Dermatology and STD, Apex Regional STD Centre, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India

Correspondence Address:
Ashok Saxena,
A 80 FF Defence Colony, New Delhi - 110 024
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None

DOI: 10.4103/ijstd.ijstd_30_22

Background: According to the World Health Organization, 6 million cases of syphilis occur every year. Serological tests for syphilis form the mainstay of diagnosis for syphilis. We evaluated the performance of point-of-care test (POCT) against other specific treponemal test for confirming the diagnosis of syphilis. Materials and Methods: Does performance and operational superiority of POCT make it the investigation of choice in confirming syphilis? Retrospectively, data were analyzed of 599 serum samples from Apex Regional sexually transmitted disease centre, Safdarjung Hospital, New Delhi, received for testing by syphilis treponemal assays (both nontreponemal reactive and nonreactive). These samples underwent treponemal testing for syphilis by the Treponema pallidum hemagglutination (TPHA), fluorescent treponemal antibody absorption test (FTA-ABS), and POCT. Performance characteristics (sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV], and diagnostic accuracy), and operational characteristics of POCT and TPHA were evaluated against the gold standard FTA-ABS. Results: A total of 599 samples were evaluated, of which 61.76% were positive by FTA-ABS. On analysis, the sensitivity was 91.08% and 91.89%, specificity was 89.08% and 87.34%, PPV was 93.09% and 92.14%, NPV was 86.08% and 86.96%, and diagnostic accuracy was 90.32% and 90.15% for POCT and TPHA, respectively. The lower cost, shorter turnaround time, lesser infrastructure and workforce need, and easy availability make the POCT operationally superior to TPHA. Conclusion: Owing to its operational superiority and higher specificity POCT can replace TPHA for confirming the diagnosis of Syphilis. POCT are affordable, equipment free, have room temperature storage, and yield result within 15 minutes, enabling same day testing and treatment. It can be used in a resource limited setting, for community setup or even self-testing.


Print this article
Search
 Back
 
  Search Pubmed for
 
    -  Bhargava A
    -  Nagia S
    -  Verma P
    -  Bansal S
    -  Khnuger N
    -  Saxena A
 Citation Manager
 Article Access Statistics
 Reader Comments
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1022    
    PDF Downloaded29    

Recommend this journal